Pentair easy touch troubleshooting. Oct 1, 2008 · EasyTouch® 8 and 4 Pool and Spa Control System Kit Contents The following items are included in the EasyTouch® 8 and EasyTouch 4 control system kit which may also include the IntelliChlor cell. If any items are missing please contact technical support. † EasyTouch control panel (mounted in the load center) † EasyTouch load center enclosure

tomzo. This post is just to pass along my recent experience. I was foolishly working on some wiring connections with my motherboard powered on when I shorted out two wires connected to the Aux Extra relay input. The magic smoke was released from the motherboard and it tripped the 18V AC breaker. No combination of disconnecting wires …

Pentair easy touch troubleshooting. Step 2. Manually test the salt level with salt test strips or an electronic salt tester. If the salt level is in the proper range of 3000-4200, proceed to step 3. If not, adjust the salt level to the proper parameters before recalibrating. Click here to view test kits.

Share. 2.7K views 6 months ago #pentair #easytouch. We troubleshoot and fix a pool control board from Pentair after a lighting strike in the area. The surge took out communications with the pump ...

Pentair Pool Filters, Pool Pumps, Pool Heaters, Pool Lighting & Pool Automation Call Us: 1-800-831-7133Wireless connection kit for intellitouch and easytouch control systems (12 pages) Control Systems Pentair EasyTouch 8 and 4 Installation Manual. Pool and spa control system (with optional intellichlor electronic chlorine generator) (32 pages) Control Systems Pentair IntelliCenter 522039Z Installation Manual.

If your fridge isn’t keeping your food cold, it can be a hassle to figure out what’s wrong. Fortunately, there are some simple steps you can take to troubleshoot the problem and get your fridge back up and running. Here’s an easy guide to t...Oct 25, 2017 · If you have something else on the buss, like ScreenLogic or a SWG and they work, then the problem will not be the EasyTouch's communications buss. So, step one is to ensure the date cable is connected at the pump and inside the EasyTouch. Step two is to see if the pump's display reads "Display not Active." Jul 13, 2017. #1. I've got an EasyTouch 4-circuit / IntelliChlor that won't communicate with the variable speed pump. I can turn the pump on by pushing one of the 4 button on the pump itself but when it's in "running schedule" mode it doesn't do anything. The Salt Cell comes on during the scheduled time but the pump doesn't.Thanks, I didn't know 146 represented a combination of codes. Per the manual: 1 = LCD backlight (false error, no problems). 4 = Switch (buttons) - all buttons seem to work just fine. 6 = Sensor/Relay/Valves test (Must be a sensor failure; no problem w/ relays and no actuated valves installed).About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...Jun 27, 2019 · 3. Everything Else Mar 19, 2023. ogdento. Forums. Equipment - Build, Use, and Repair. Everything Else. After a recent power outage, I noticed my Easytouch remote said "No Comm". Ive researched and tried all of the methods recommended for reestablishing connection between the the remote and the main unit. After everything failed I called Pentair. Remotely manage from a Mac® Computer or PC using the ScreenLogic2 Interface application. Easily change, track and monitor history of pH and ORP levels when using the IntelliChem® Water Chemistry Controller with IntelliTouch® or EasyTouch® automation systems. ScreenLogic2 app now allows full-color lighting control for both IntelliBrite® LED ...Pentair EasyTouch "NO COMM" Thread starter Steve3; Start date Aug 11, 2019; Tags aquacal communication problem easytouch Jump to latest Follow Reply Forums. Equipment - Build, Use, and Repair. Everything Else . S. Steve3 New member. Aug 11, 2019 3 Saratoga, NY. Aug 11, 2019; Add bookmark #1 I just replaced a circuit …tomzo. This post is just to pass along my recent experience. I was foolishly working on some wiring connections with my motherboard powered on when I shorted out two wires connected to the Aux Extra relay input. The magic smoke was released from the motherboard and it tripped the 18V AC breaker. No combination of disconnecting wires …

Nov 5, 2021 · If you have any questions please contact us through our website at: https://www.poolspecialists.com/ When your Maytag refrigerator isn’t cooling, it can be a major inconvenience. Fortunately, there are a few troubleshooting tips that you can try to get your refrigerator back up and running. Here are some steps you can take to get your Mayt...Mar 26, 2022 · These Pentair MasterTemp 400 Problems relating to temperature are explored below. i) No Heat. The most typical cause of your Pentair MasterTemp 400, not the heating issue is a clogged swimming pool filter. Solution: Low water flow is the cause of up to 70% of all ‘My heater won’t heat’ service calls. Jul 13, 2017. #1. I've got an EasyTouch 4-circuit / IntelliChlor that won't communicate with the variable speed pump. I can turn the pump on by pushing one of the 4 button on the pump itself but when it's in "running schedule" mode it doesn't do anything. The Salt Cell comes on during the scheduled time but the pump doesn't.

This video is a quick tip guide to making sure your Pentair Screenlogic 2 Transmitter or Screenlogic 2 antenna is working at it’s optimum. We’ll give a few t...

1.) the box (no longer controls pumps), booster turns on automatically. 2.) the board/wiring to see if there is an issue. Note the comm is intentionally disconnected as it runs to the wireless which is fried. 3.) the variable speed pump -- both with power, and then when manually started.

If you have any questions please contact us through our website at: https://www.poolspecialists.com/We troubleshoot and fix a pool control board from Pentair after a lighting strike in the area. The surge took out communications with the pump and ScreenLogi...Jul 13, 2017. #1. I've got an EasyTouch 4-circuit / IntelliChlor that won't communicate with the variable speed pump. I can turn the pump on by pushing one of the 4 button on the pump itself but when it's in "running schedule" mode it doesn't do anything. The Salt Cell comes on during the scheduled time but the pump doesn't.264. Jun 29, 2020. #7. OK, disconnected all the wires that plug into the Easytouch board except power. Same Issue flashing Solar (Aux Extra) light. Updated firmware from 2.140 to 2.180, no change with light flashing. Ran self test under one of the menu's, and The results was "Failed Code 4", googled the code and Dr. Google said a …Easytouch PL4/PSL4 Control System Outdoor Control Panel Operating Modes. 21. Quick Start Spa and Pool Operations. 22. Heat Your Spa or Pool (Manual Control) 22. Adjust the Water Temperature Settings. 22. Schedule Start and Stop Times for Equipment.

IMPORTANT WARNING AND SAFETY INSTRUCTIONS Important Notice: Attention Installer: This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner and/or operator of this equipment.Hi Gary.I have an easy touch remote that say no comm. I have tried readdress but my remote say address lock and never finds the control panel . I looked at the 3 lights and the power is on but the other two blink together 5 times than stop then the 485 blinks once.Aug 18, 2018 · My scheduled run tines include regular filtration, suction side cleaner, and the 3 waterfall periods. There are never more than 2 schedules that overlap (e.g., the filtration timer is running and then the waterfall kicks in for 30 minutes during the time period. The cleaner period, with a higher pump rpm speed, comes later). Are you having trouble with your Maytag washer? Don’t worry, you’re not alone. Many people have experienced issues with their Maytag washers, and it can be difficult to know where to start when it comes to troubleshooting.1. With the power off I would disconnect ScreenLogic from the EasyTouch's com port. Disconnect the SWCG by unplugging the cable at the EasyTouch. Disconnect the pump from the EasyTouch by unplugging the cable at the pump. 2. Turn the power on to the pump and test the pump to make sure it responds to commands from the pump's …Pentair Easytouch 8 Wireless Troubleshooting. Step 1. Inspect the LX Control Center (the spa's control box) to confirm that it's receiving power, if the remote's power light isn't illuminating ... Step 2. Step 3. Step 4. Step 5.This session of Pool School by Presidential Pools, Spas & Patio Service Manager, Bill Watson, explains how to program the Pentair Easytouch Automation Panel.The heater display board gives a CEr indicator (communication problem). Likewise, my 9-year-old Pentair EasyTouch remote control system in the house now indicates "NO COMM." A tech recently replaced the AquaCal display board with a new-style board, and before the circuit breaker failed the heater had been working well.The EasyTouch control system menu features let you create customized schedules for your pool and spa equipment, heat temperatures, and chlorination settings to switch on and off at a set day and time. Page 11 10 minutes to allow the heater to cool down. Pentair heaters do not require a cool down time.Pentair pool products lx-100ez easytouch pool/spa control system installation and owner's manual (32 pages) Control Systems Pentair EasyTouch PL4 User Manual (80 pages) ... Page 73 OK - No Problems Detected see: Tap Status on the Home screen to Pump appears to be running normally. Click display the current pump status and here to view …Pentair Pool Filters, Pool Pumps, Pool Heaters, Pool Lighting & Pool Automation Call Us: 1-800-831-7133 Water Pool and Spa, Inc. (“Pentair”) with any questions regarding this product. This product is intended for use in swimming pool applications only. Most states and local codes regulate the construction, installation, and operation of pub- ... EASYTOUCH® PL4/PSL4 Control Systems Power Center Installation Guide EasyTouch ...SWG Type. Hayward Aqua Rite (T-9) Sep 28, 2019. #4. I’d do 2 things: as Jim mentioned, double check the EasyTouch menu that Spa-Side remote is ‘Enabled’. Check the 4-wire connectors at the low voltage panel on the EasyTouch. Sounds like you’ve got multiple wires going in and they tend to get poor connections this way.IntelliTouch pool and spa automation offers superior control systems from the simplest to the most ambitious pool and spa designs, including water features and spectacular pool lighting effects. IntelliTouch systems offer innovative technology and a wide range of wireless and wired control panels that are easy to program with simple menus.Jun 25, 2018 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ... EasyTouch® 8 and 4 Pool and Spa Control System Kit Contents The following items are included in the EasyTouch® 8 and EasyTouch 4 control system kit which may also include the IntelliChlor cell. If any items are missing please contact technical support. † EasyTouch control panel (mounted in the load center) † EasyTouch load center enclosureHi Gary.I have an easy touch remote that say no comm. I have tried readdress but my remote say address lock and never finds the control panel . I looked at the 3 lights and the power is on but the other two blink together 5 times than stop then the 485 blinks once.

Jun 21, 2016 · Jun 21, 2016. #1. We have a Pentair EasyTouch 8 control system for our in-ground pool and this past weekend, following a fairly severe electrical storm, neither the filter nor cleaner pump was working. When I went to investigate I found that the only apparent problem was that the low voltage circuit breaker that is labeled "Relays" was open. Page 66: Section 3 - Troubleshooting (such as circuits with freeze protection, etc.). The second relay switches the pump from low speed to high speed. The default condition is low speed. Up to seven circuits …Page 1 EASYTOUCH PL4/PSL4 CONTROL SYSTEM ® FOR POOL AND SPA USER’S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS...; Page 2 Customer Service / Technical Support USA Phone: (800) 831-7133 8 A.M. to 7:30 P.M. (ET) Fax: (805) 284-4151 Web sites visit www.pentairpool.com and staritepool.com P/N 522461 Rev. C 2/2020... Knowing how to troubleshoot issues with your vacuum cleaner is one sure way of extending its service life and getting the most bang for your buck. It does suck to have a vacuum cleaner that doesn’t suck.! " # $%& 2 -1 9 -0 4 / ( )* +,--.' - . ) ! /0 1 &/; 2 4 0 < . : &) . 1 ! . : w a r n in g r is k o f e l e c t r ic a l s h o c k o r e l e c t r o c u t io nSummary of Contents for Pentair EASYTOUCH PL4. Page 1 EASYTOUCH PL4/PSL4 CONTROL SYSTEMS ® FOR POOL AND SPA INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS... Page 2 Customer Service / Technical Support USA Phone: (800) 831 …Aug 10, 2015 · 1) Pressing the 'Filter Pump', what I would perceive as a command to turn the pump off, button with the panel on causes the pump to ramp up to a high speed. 2) Pressing the 'Pump Low' causes the pump to ramp up. I did not not the RPM. When the panel completes the schedule and turns off, local control is given to the pump.

INFORMATION AT YOUR FINGERTIPS. Stay smart, connected and protected with the Pentair Home app. This product is one of a range of connected products from Pentair that gives you command of your …These Pentair MasterTemp 400 Problems relating to temperature are explored below. i) No Heat. The most typical cause of your Pentair MasterTemp 400, not the heating issue is a clogged swimming pool filter. Solution: Low water flow is the cause of up to 70% of all ‘My heater won’t heat’ service calls.Sensor can be is used with IntelliCenter, IntelliTouch, EasyTouch, SunTouch and Compool to EasyTouch Upgrade Control Systems. Related manuals IntelliCenter™ Control System User’s Guide (P/N 522990) IntelliTouch® Control System User’s Guide (P/N 521075) EasyTouch® Control System User’s Guide (P/N 521044) Knowing how to troubleshoot issues with your vacuum cleaner is one sure way of extending its service life and getting the most bang for your buck. It does suck to have a vacuum cleaner that doesn’t suck.Are you having trouble with your Maytag washer? Don’t worry, you’re not alone. Many people have experienced issues with their Maytag washers, and it can be difficult to know where to start when it comes to troubleshooting.The SolarTouch Solar Control System offers full digital control for the most precise, efficient, swimming pool heating possible. The digital thermostat is set with the touch of a button and will monitor the temperature of your pool water and solar collectors. Digital calibration of water and solar temperature in 1° increments. HOURS. Mon : 10am – 4pm Tue : 10am – 4pm Wed : 10am – 4pm Thu : 10am – 4pm Fri : 10am – 4pm Sat : 9am – 1pm Sun : CLOSEDFebruary 09, 2020 Communication issues are among the most common problems people run into with their Pentair pool equipment. The following problems can be caused by faulty communication: pressing a button on a remote or indoor controller does nothing an Intelliflo pump won't run the schedule screenlogic can't control the system7. Delray Beach, FL. Oct 28, 2018. #1. I have a new Pentair EasyTouch PL4 that currently only running the pump and the pool light. The pool light works on the schedule just fine, but the pump runs continuously when in Auto mode. It does not follow the schedule. I entered a schedule for Pool and used all the default settings.1.) the box (no longer controls pumps), booster turns on automatically. 2.) the board/wiring to see if there is an issue. Note the comm is intentionally disconnected as it runs to the wireless which is fried. 3.) the variable speed pump -- both with power, and then when manually started.INTELLICHEM ® Water Chemistry Controller Installation and User s Guide ii IMPORTANT WARNING AND SAFETY INSTRUCTIONS WARNING CHEMICAL BURN HAZARD: Make sure all pumps are switched off at the main circuit breakers at the house before drilling intoassumes that all system equipment has been properly installed and connected to the EasyTouch Load center. Testing Valve Actuators and Pumps: Use the following steps to test the valve actuators (CVA24T) for proper rotation. To test the valve actuators and pump: 1. Switch on the electrical power at the house breaker. 2. Switch on …Perform your own maintenance by following a few simple steps, and you will save yourself frustration, time, and money. You can examine the power connection to your LX Control …Pentair EasyTouch 4 Pdf User Manuals. View online or download Pentair EasyTouch 4 User Manual, Installation Manual ... Section 3 - Troubleshooting. 66. Frequently ... Connecting an iPad to a printer can be a tricky process, but with the right troubleshooting tips and techniques, you can get your device up and running in no time. Here are some helpful tips on how to connect an iPad to a printer.From https://www.justanswer.com/ythiJustAnswer Customer: I have a pentair easy touch that is reading "no comm" after power went out to house during storm.Jus...Pool Automation that is Simple and Affordable. The EasyTouch Control System eliminates the inconvenience of trips to your pool equipment pad, memorizing operating sequences, opening and closing valves and resetting time clocks and thermostats. With push-button operation and clear, intuitive instructions and displays, your EasyTouch system ... SWG Type. Hayward Aqua Rite (T-9) Sep 28, 2019. #4. I’d do 2 things: as Jim mentioned, double check the EasyTouch menu that Spa-Side remote is ‘Enabled’. Check the 4-wire connectors at the low voltage panel on the EasyTouch. Sounds like you’ve got multiple wires going in and they tend to get poor connections this way.

With four different configurations available, there’s an EasyTouch system to fit every pool and spa. The EasyTouch PL4 control system is a four-circuit system designed for a single body of water, while the EasyTouch PSL4 system is a four-circuit system designed to control a pool/spa combination. For even greater control, add an optional

Jul 7, 2017 · Pentair Easy Touch with Remote. I am new home owner and the remote was working, now intermittently works. I tried Reset for panel and remote, also your 4/24/2015 re Wireless Address. Remote says 'Addr … read more

The Pentair Home app range of connected products help you enjoy water with our innovative, energy-efficient pool solutions. Control your swimming pool system and monitor water chemistry from one easy-to-use dashboard on your smart device! Receive alerts sent directly to your phone — and if you choose, to your trusted pool professional.*.IMPORTANT WARNING AND SAFETY INSTRUCTIONS Important Notice: Attention Installer: This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner and/or operator of this equipment.How to dissemble and repair Pentair Easy Touch 8 button remote I thought I would post my experience so other people can benefit. My power button stop working on the remote. To open the remote I used a Dermel tool with a diamond blade. I had to cut all the around the outside. Once open I saw the ribbon cable to the front board had …• EasyTouch 8 and 4 Pool and Spa Control System User’s Guide (P/N 520584) • EasyTouch 8 and 4 Installation Guide (P/N 520583) EasyTouch Accessories EasyTouch Indoor Control Panel, 4 Circuits (P/N 520548) EasyTouch Indoor Control Panel, 8 Circuits (P/N 520549) EasyTouch Wireless Control Panel, 4 circuits (P/N 520546)Product owners manuals are available for nearly every product to help you and your pool professional install and service your pool and spa equipment and accessories. The manuals and guides are organized by equipment category. Select the category of interest to view a list of available owners manuals. For additional product information, please ...Pentair Intellichlor IC-60. Mar 1, 2017. #5. Check the antenna that connects to the main panel. Make sure all the connections are solid. The antennae (both for ScreenLogic and the RF remote....looking at you Jim!!) are susceptible to getting fried by power surges and what not. You might need to replace it.Apr 19, 2022 · I have Pentair EasyTouch control system with IntelliPH acid dispenser and Intellichlor IC40 SWG. I recently performed a pump head tube replacement on the IntelliPH. Shortly after doing so I noticed no power to my IC40. Upon further review I noticed the 12amp Intellichlor breaker was tripped. I reset and 10-20 minutes later it trips. IntelliTouch pool and spa automation offers superior control systems from the simplest to the most ambitious pool and spa designs, including water features and spectacular pool lighting effects. IntelliTouch systems offer innovative technology and a wide range of wireless and wired control panels that are easy to program with simple menus.

choppy bob hairstyles for thick hairamateur naturist videosterra and sky plus size shortsxfinity wifi extender pods Pentair easy touch troubleshooting soundboard sounds download for voicemod [email protected] & Mobile Support 1-888-750-8569 Domestic Sales 1-800-221-4747 International Sales 1-800-241-7561 Packages 1-800-800-3815 Representatives 1-800-323-9147 Assistance 1-404-209-7024. 5. Pumps, Filters, and Plumbing Oct 3, 2023. Faiz360. This was working until I started playing with the programming. I wanted to change the times that the system would turn on and then turn off and wanted to make sure that the solar heater would turn on when the pumps started. Now it is not turning off once it turns itself on, I.e.. aerie pool party cover up If you have something else on the buss, like ScreenLogic or a SWG and they work, then the problem will not be the EasyTouch's communications buss. So, step one is to ensure the date cable is connected at the pump and inside the EasyTouch. Step two is to see if the pump's display reads "Display not Active."Sensor can be is used with IntelliCenter, IntelliTouch, EasyTouch, SunTouch and Compool to EasyTouch Upgrade Control Systems. Related manuals IntelliCenter™ Control System User’s Guide (P/N 522990) IntelliTouch® Control System User’s Guide (P/N 521075) EasyTouch® Control System User’s Guide (P/N 521044) p0int click care cnacostco premium gas price near me Heat pump troubleshooting guide for Pentair pool heaters. Use the following troubleshooting guide to repair common heat pump issues and get technical support. Call Us Nationwide: 1-800-741-9956. West: 213-291-9276 Southwest: 214-764-8551 Midwest: 312-229-0026 Northeast: 631-223-7175 Southeast: 239-247-5878 or 954-866-1644. … liquid imagination strain leaflywhen life gets hard keep on marching on New Customers Can Take an Extra 30% off. There are a wide variety of options. I'm having a problem with the temperature readings on my IG spa/pool.....pool equipment (Pentair Easy Touch) is reading 116 degrees while the actual temp is more like 74 degrees. I tried to recalibrate the temp under settings, but the change doesn't stick for some reason.Pool Product Warranties. Filtration Product Warranties. Pool and Spa Calculators. Pool Product Registration. Rebate Center. Product Manuals and Downloads. Pentair Home App. If you're feeling alone in the management of your residential pool, just know that Pentair is here to help you out. Don't miss out on our support! PENTAIR AQUATIC SYSTEMS 1620 HAWKINS AVE., SANFORD, NC 27330 • (919) 566-8000 10951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 • (805) 553-5000 WWW.PENTAIRPOOL.COM All Pentair trademarks and logos are owned by Pentair, Inc. Pentair Aquatic Systems™, EasyTouch ®, IntelliTouch, and