Chlorinator off high salt amps - High salt/amps Salt has been tested and is 3100, new t-cell purchased and still getting the message. Contractor's Assistant: I understand that youre experiencing high salt/amps despite testing the salt level and replacing the t-cell, but dont worry, our Expert will be able to help you troubleshoot and resolve this issue.

 
Only chlorinator off, test salt level (which is the problem), instant salt chlorinator off, flow switch- flow, cell temp sensor-82f, water sensor-open circuit, air sensor-open circuit. Main software Rev 4.45, display software Rev 3.13.. 24 hour fitness sport san francisco photos

Home - Trouble Free Pool | Trouble Free PoolPL35+. Take salt chlorination to the next level with the Pool Lab Plus Series. All the great features of the PL Classic series, plus the ability to connect and control both the Pool Lab Auto Sampling Photometer (ASP) and the Spa Flow Switch. Features & Benefits. Connect to the ASP Gain full chlorine and pH control by connecting the Pool Lab ASP.Check Salt High Salt Inspect Cell Maximum Current (Amps) before shutdown T-Cell 3: 4.15 T-Cell 5: 6.40 T Cell 9: T Cell 15: 9.50 10.00 If salt level is above the range, partially drain pool and/or spa and refill with fresh water to achieve a salt level of 3200ppm. ( RULE of THUMB: Each inch of water drained will reduce the salt level IOOppm ...If all zeros or if Chlorinator Off Percentage Met, press ~+ key. IF, after a short countdown delay, the display does not revert to zeros, refer to step 3. NOTE: The main circulation pump MUST be ON and the chlorinator AND flow switch MUST have flow to successfully complete this process. 2 Above is an example of the updated instant salt reading ...Check the Timer settings. The chlorinator turns on then turns off. The circuit breaker may be tripping. This can be due to excessively high salt levels. There may be a short across the Cell plates. Check the Cell …Hayward Aqua plus says “chlorinator off high salt amps”. ... High salt/amps Salt has been tested and is 3100, new t-cell purchased and still getting the ...Feb 22, 2020 · I have a pro logic that’s about 7 years old and my salt cell went out late summer. I replaced it with one I bought off Amazon, everything been fine until the other day when I received the message chlorinator off/high amps. I went to diagnostics and voltage is +40.58V 10.08A 3000PPM. Any help on... Step 5. Check Salt Level - Most salt chlorine generators will shut down the cell's salt levels are outside the prescribed range. For example, the Pentair Intellchlor’s operational salinity range is 3000 - 4200 ppm (ideal 3400 ppm.). If the salt level is outside of this range, the CHECK SALT light will flash, and the cell will shut down until ...I have an aqua rite salt chlorine system with a T-15 turbo cell. My average salt reading is 2100ppg and the instant reading is 210ppg. The check salt and inspect cell lights are constantly on (not bli … read moreI have a pro logic that’s about 7 years old and my salt cell went out late summer. I replaced it with one I bought off Amazon, everything been fine until the other day when I received the message chlorinator off/high amps. I went to diagnostics and voltage is +40.58V 10.08A 3000PPM. Any help on...Chlorine is most effective when the pH of your pool water is 7.4. The electro-chemical process of the chlorinator, (change salt into chlorine) will automatically raise the pH of your pool water, so it is very important to check your pH weekly and adjust as necessary. Winter You should set your Chlorinator to operate for 6 to 8 hours per day.There is one main factor to consider first when a salt chlorine generator fails, and that is the presence of phosphates in the pool water. When levels of phosphate exceed 500 ppb the unit can cease to produce enough free available chlorine to keep up with demand. Most manufacturers of salt chlorine generators will confirm that when …Aug 23, 2009 ... ... Salt, High Salt, and ... The Goldline tech said the “High Salt/Amps ... Make sure you turn your chlorinator Off for 24 hours every time you add salt ... Push 3, Cell Amperage - The cell's average amperage when chlorine is being generated varies with the size of cell installed: T-15 is 3.1 to 8.0 amps; T-9 is 2.3 to 6.7 amps; T-5 is 1.9 to 5.7 amps; and t-3 is 1.3 to 4.5 amps. When the cell is not generating chlorine the amperage is 0. A chlorinator off high salt amps indicates that the amount of chlorine being produced is too low. This can be caused by an insufficient level of salt in the pool water, or a malfunctioning chlorinator. To fix this issue, you should first check the concentration of salt in your pool – it should be between 2700 and 3400 parts per million (ppm). ...Volts & Amps Guide. Please note: • Warmer water and higher salt will decrease voltage. • Colder water, lower salt, scaled, or depleted cell will increase voltage. • It is better to run on a lower power level and higher output percentage, than a higher power level and lower output percentage. Please note: • Warmer water and higher salt ...The optimal voltage range for chlorinator cells varies depending on the specific make and model. It is crucial to consult the manufacturer’s documentation or user manual for the recommended voltage range. Generally, the voltage range falls between 5 to 7 volts for most chlorinator cells. Operating the cell within the specified voltage range ...rated for minimum 6 Amps and tested on a regular basis by pushing the test button. If the GFCI fails to ... “all in one” salt chlorinator. CircuPool’s high performance systems offer escape from the routine of manual pool ... leave the salt chlorinator off any time there is a chance of recently added chemicals going through the salt cell ...When salt reading drop bellow 2300 ppm is Aqua Rite will shoot down output to cell( generating LED off). Chlorine generation will stop even actual salt level in pool is 2500-3400 ppm. But cell is still OK and can generate chlorine. Problem is caused by salinity sensor that is part of cell, so we need to clean,calibrate it or replaced.Chlorinator Off - High Salt/Amps Error Message Test the salt level in the pool using a suitable tester. Be sure the tester has been calibrated and is clean. Pool water will have to be removed and fresh water added to reduce the last level to the 3200 PPM level if found to be higher. Check to make sure system is configured for correct model cell.I have a high salt amps message. chlorinator off when I start chlorinator the values that come up are,40.58V, 1O.08a. 83F and 1900 ppm. I also replaced the cell yesterday. read moreMake the Switch to Saltwater This isn’t a total chlorine workaround, but you won’t have to add chlorine to your pool again. Basically, a saltwater pool uses a salt cell to make chlorine on-site. That means that it’s also super stable, low chlorine levels. As a result, a saltwater pool has less irritating water.I've bought after market new t-15 salt cell and put in new board for t-15 cell and still reads high salt 4200 compared to pool store water sample 3200ppm, don't know what else to try. Changed sand in …The Hydrochlor Mineral Chlorinator includes an energy saving, intelligent power pack that makes it easy to keep your pool sanitised and healthy to swim in. Chlorination. The main function of the Hydrochlor Mineral Chlorinator is to produce chlorine to sanitise the pool water. Pool water, which contains dissolved Mineral Crystals / pool salt ...I recently used chlorine bleach to clean the siding on my house, and I was amazed at how well it worked! What is bleach? How does it remove stains? Is the chlorine in bleach the sa...The chemical formula for salt is NaCl. Salt consists of one atom of sodium combined with one atom of chlorine. The scientific name for salt is sodium chloride. Salt is an ionic com...JustAnswer-Q&A. 8.12K subscribers. Subscribed. 0. 1.2K views 2 years ago. From https://www.justanswer.com/ythi JustAnswer Customer from San Antonio, TX: I have the "Chlorinator off High...Oct 7, 2019 · I just replaced my T-cell 15 Turbo cell with a new T-cell 15. When the system begins to run I get this message, "Chlorinator Off High Salt/Amps." Then later in the messages I get, "Check System High Salt/Amps." I checked the instant salt reading and it is 4800, which I know is way too high. I... Chlorinator off High Salt/Amps. Post by Kabo24 » Sun 26 Jun, 2016 20:56 . Help please! My salt was high in my pool and got a high salt amps chlorinator off reading. I drained some water, salt was tested by Leslie's and salt is at 3200ppm. Tested salt cell (brand new) and is working properly. I am still getting the "chlorinator off high salt ...I. ‘High Salt’ Light Stays On. The ‘High Salt’ light will stay on for several reasons including: cell amperage is above the maximum limit, the control is set to the wrong turbo cell, or you simply have too much salt in your pool. The LCD display will read “HI”. Remedies. Independently verify the salt levels in your swimming pool.I just replaced my T-cell 15 Turbo cell with a new T-cell 15. When the system begins to run I get this message, "Chlorinator Off High Salt/Amps." Then later in the …When salt reading drop bellow 2300 ppm is Aqua Rite will shoot down output to cell( generating LED off). Chlorine generation will stop even actual salt level in pool is 2500-3400 ppm. But cell is still OK and can generate chlorine. Problem is caused by salinity sensor that is part of cell, so we need to clean,calibrate it or replaced.Too high - add muriatic acid Alkalinity 80 - 120 ppm Salt 2700 - 3400 ppm Add salt as required to increase. ... determined by turning the equipment off and on, then the user is encouraged to try to correct the interfer- ... the salt into free chlorine which kills bacteria and algae in the pool/spa. Chlorine will revert back to sodium chloride ...I have the "Chlorinator off High salt/amps" message. Contractor's Assistant: I'll do all I can to help. How long have you been dealing with this? I replaced the CG a couple of months ago and currently it is reporting 4600 PPM on the salt. just this past week, and the pool turned green on me wed-today I shocked at lunch to get the green cleared up, but bigger concern is the CG not generatingTest the water that water has just left the chlorinator - it should have a very high chlorine reading. (Remember that if it is extremely high it may bleach the test tablet so you may …Also called Saltmaster on some chlorinators. This model has 4 connections. Quality Australian made cell. ... Due to high demand, we recommend reaching out to us directly for the most up-to-date stock. ... Take 20% off your first order. 20% off. Enter the code below at checkout to get 20% off your first order. CODESALE20Turn your Chlorinator down to its lowest setting (10-20%) If you're manually dosing your pool Liquid Chlorine or Granulated Chlorine, stop adding Chlorine until it is back down to normal range on your test strip. Avoid swimming, or wear goggles if you do. Check Stabiliser (UV Blockout) levels and ensure that levels are a max 30 - 50ppm on your ...Nasalcrom (Cromolyn Sodium Nasal) received an overall rating of 8 out of 10 stars from 14 reviews. See what others have said about Nasalcrom (Cromolyn Sodium Nasal), including the ...We recommend that pool owners choose a cell size that is at least 1.5 – 2.0 times their pool size. This means the cell would not need to work as hard to keep up with your chlorine needs. Save money with the CP-15 Replacement Cell for Aqua Rite T Cell 15. Question: My salt system reads Check System HI salt/amps and is not making chlorine.STEP 1C: Starting with the average salt reading. Turn the switch to ‘Off’, then back to ‘Auto’. Wait for the relay to click (about 5 to 10 seconds). STEP 2: Press the ‘Diagnostics’ button 5 times, this will bring up the instant salt reading. The instant salt reading will start as - 0.Jul 11, 2021 · From https://www.justanswer.com/ythiJustAnswer Customer: I have a high salt amps message.JustAnswer Customer: chlorinator off when I start chlorinator the va... Check Salt High Salt Inspect Cell Maximum Current (Amps) before shutdown T-Cell 3: 4.15 T-Cell 5: 6.40 T Cell 9: T Cell 15: 9.50 10.00 If salt level is above the range, partially drain pool and/or spa and refill with fresh water to achieve a salt level of 3200ppm. ( RULE of THUMB: Each inch of water drained will reduce the salt level IOOppm ...chlorine production by measuring the amps drawn by the chlorinator cell in each polarity. 1. Switch power to the Pool Lab salt chlorinator off at the power outlet and wait at least 10 seconds. 2. If there is a Pool Lab ASP (Auto Sampling Photometer) connected, unplug it from the port at the bottom of the power pack. My salt was high in my pool and got a high salt amps chlorinator off reading. I drained some water, salt was tested by Leslie's and salt is at 3200ppm. Tested salt cell (brand new) and is working properly. I am still getting the "chlorinator off high salt/amps" reading and it's telling me that the salt is at 1900ppm. Set TurboCell® Type & Reset Average Salt 10-11 Adjust Chlorine Output & Clean TurboCell 12-15 Troubleshooting: Pg. 16-38 1. Check Salt & Inspect Cell: flashing or ON 17-20 2. High Salt: LED ON 21-25 3. No Flow: LED flashing or ON 26-30 4. Display ONLY, Lights ONLY, or Neither 31-36 5. LCD: Displaying HOT or COLD _ 37-38I have a high salt amps message. chlorinator off when I start chlorinator the values that come up are,40.58V, 1O.08a. 83F and 1900 ppm. I also replaced the cell yesterday. read more Push 3, Cell Amperage - The cell's average amperage when chlorine is being generated varies with the size of cell installed: T-15 is 3.1 to 8.0 amps; T-9 is 2.3 to 6.7 amps; T-5 is 1.9 to 5.7 amps; and t-3 is 1.3 to 4.5 amps. When the cell is not generating chlorine the amperage is 0. This comes in handy when it comes to determining the best solution. Below are 3 of the most common causes of failure in the salt cell’s function. 1. Wear and tear due to continuous use. This usually leads to problems like PCB electric failure and disconnection of plates. 2. High salt concentrations in water.I just replaced my T-cell 86 Turbo cell with a newly T-cell 54. When the system starting in race I get this message, "Chlorinator Off Elevated Salt/Amps." Then late for the messages I get, "Check System High Salt/Amps." I checked the instant salt reading and it is 8147, which EGO know is way too great. I...Check Salt High Salt Inspect Cell Maximum Current (Amps) before shutdown T-Cell 3: 4.15 T-Cell 5: 6.40 T Cell 9: T Cell 15: 9.50 10.00 If salt level is above the range, partially drain pool and/or spa and refill with fresh water to achieve a salt level of 3200ppm. ( RULE of THUMB: Each inch of water drained will reduce the salt level IOOppm ...However, when I tested it with the salt strip again, it read 2800ppm. This salt level would be fine for the regular salt chlorinator but I found nothing online about a low salt chlorinator. Does anyone know if 2800ppm is too high for a low salt chlorinator system? I also plan on just taking a sample of water for professional testing tomorrow.I have an aqua rite salt chlorine system with a T-15 turbo cell. My average salt reading is 2100ppg and the instant reading is 210ppg. The check salt and inspect cell lights are constantly on (not bli … read moreOnce your salt chlorinator is turned off, it is safe to add salt to your pool. It is then crucial to run your pump system consistently for the next 24 hours to allow the newly added salt to dissolve and be adequately distributed through the water. Many pool owners skip this step, or simply forget to override the timer on their pump system. How To Tell If Salt Cell Needs Replacing | Best Price Pool Equipment. Skip to content. Fast Delivery Available! 211 Stirling Highway, Claremont, WA 6010. 0412 561 620. Email Nicole. About Nicole. Nicole’s Advice. Warranty. I've bought after market new t-15 salt cell and put in new board for t-15 cell and still reads high salt 4200 compared to pool store water sample 3200ppm, don't know what else to try. Changed sand in … If the chlorine is still low or hasn’t increased, try increasing the power to 70%. If the chlorine level is too high, back off the power. Keep adjusting and testing until you have a stable chlorine level (which should be 3-5 ppm). 7) Algae Using Up Chlorine . There may not actually be anything wrong with your salt cell or chlorinator. Switch off the filter pump and chlorinator and close the necessary valves. Unplug the cell terminal cap. Unscrew the electrode retaining ring and remove the electrode. Immerse the electrode in a self-cleaning solution, …The shock is great but that doesn't address the salt cell and the shock will wear off. Make sure the ph is in the 7.2 to about 7.8 range and your Calcium which is the big reason you have to clean the cell less than 450 ppm.I have a Hayward goldline pro logic with a message that reads chlorinator off high salt amps. The values are at 40.58v, 10.08a. ... System check, chlorinator off very ...The E Series Salt Chlorinator offers affordable, reverse polarity self cleaning technology in a simple to use, easy to install yet robust and reliable product. ... 8.9 amps Equipment: Clock timer settings: 2 timers Video. E25 - Setting Output. Play. Video. E25 - Connecting the Cell. Play. Video. E25 - Connecting Pump. Play.I drained some water, salt was tested by Leslie's and salt is at 3200ppm. Tested salt cell (brand new) and is working properly. I am still getting the "chlorinator …Switch power to the Pool Lab salt chlorinator off at the power outlet and wait at least 10 seconds. If there is a Pool Lab ASP (Auto Sampling Photometer) connected, unplug it …anticlockwise until the high salt (red light) goes off and the 10 chlorine output LEDs are on (1 in fig 2). If this light is the only one illuminated then the unit has gone into over temperature cutout and will reset once back to normal running temperature. 4. Polarity Light – …Home - Trouble Free Pool | Trouble Free PoolFeb 22, 2020 · I have a pro logic that’s about 7 years old and my salt cell went out late summer. I replaced it with one I bought off Amazon, everything been fine until the other day when I received the message chlorinator off/high amps. I went to diagnostics and voltage is +40.58V 10.08A 3000PPM. Any help on... This comes in handy when it comes to determining the best solution. Below are 3 of the most common causes of failure in the salt cell’s function. 1. Wear and tear due to continuous use. This usually leads to problems like PCB electric failure and disconnection of plates. 2. High salt concentrations in water.Main Takeaways. A salt chlorine generator uses salt and a process called electrolysis to sanitize your pool. The two main parts of a salt chlorine generator are the salt cell and the control board. Some of my top tips for maintaining your salt chlorine generator include: maintaining salt levels between 2,700 and 3,400 ppm, cleaning the ...My salt was high in my pool and got a high salt amps chlorinator off reading. I drained some water, salt was tested by Leslie's and salt is at 3200ppm. Tested salt cell (brand new) and is working properly. I am still getting the "chlorinator off high salt/amps" reading and it's telling me that the salt is at 1900ppm.The Vapure Salt & Mineral Chlorinator has a built-in salt regulator that allows it to function at optimal levels even if it goes above the recommended salt levels of 3,000 - 3,500 PPM. In short, where other chlorinators start to heat up when going over their recommended salt levels, the Striker will continue to chug along normally as long as it stays below that …Recommended phosphate levels in the pool water are below 200 ppb. Stabiliser: The chlorine gets broken down fast by UV. The way to stop this is to use stabiliser which acts as a sunscreen for the pool water. Recommended stabiliser levels are 30 -50 ppm. PH: Chlorine is more effective when the PH is low.Insufficient operating time of the saltwater chlorinator: Increase the daily operating time of the saltwater chlorinator.; Salt level in pool water is less than 2,000 ppm: Check the salt level, and adjust as needed. Excessive sun exposure has evaporated chlorine: Use a pool cover when the pool is not in use. Number of swimmers has increased: Increase the …When salt reading drop bellow 2300 ppm is Aqua Rite will shoot down output to cell( generating LED off). Chlorine generation will stop even actual salt level in pool is 2500-3400 ppm. But cell is still OK and can generate chlorine. Problem is caused by salinity sensor that is part of cell, so we need to clean,calibrate it or replaced.Nov 5, 2022 ... Follow these steps so your salt cell will get a correct salt level reading and restore lights/error codes! First measure out water in a ... Home - Trouble Free Pool | Trouble Free Pool Fasten the Turbo Cell to Cell Cleaning Stand with the cord side down. Before filling the Turbo Cell with a muriatic acid solution, place a container underneath to avoid any spills. Fill the Turbo Cell to the top with the solution and let soak for 15 minutes. Empty the Turbo Cell and inspect. If clean, rinse with a hose and reinstall.Low salt. The Salt Cell needs a certain amount of salt in the water to convert the salty water to chlorine. The correct salt level is important to cell life and the effective operation of your chlorinator. A typical pool of around 50,000 litres requires 200kg of salt to initially set up the pool to 4,000ppm.The shock is great but that doesn't address the salt cell and the shock will wear off. Make sure the ph is in the 7.2 to about 7.8 range and your Calcium which is the big reason you have to clean the cell less than 450 ppm.Step 5. Check Salt Level - Most salt chlorine generators will shut down the cell's salt levels are outside the prescribed range. For example, the Pentair Intellchlor’s operational salinity range is 3000 - 4200 ppm (ideal 3400 ppm.). If the salt level is outside of this range, the CHECK SALT light will flash, and the cell will shut down until ...Nov 12, 2021 ... ... Pools, Inc.•530K views · 12:08. Go to channel · Chlorinator Off No Cell Power - DIY Repair. FiveAble•90K views · 1:54. Go to channel &midd...The Viron Saltwater Chlorinator continually generates chlorine at the level you require allowing you to set and forget. With easy to use touch pad, intelligent self-cleaning of the cell, pool & spa dosing control and a filter backwash timer, you count on the Viron Saltwater Chlorinator to keep your pool looking crystal clear.

Nov 2, 2021 · Step 8: To bring the pool chlorinator level down, you will have to push the minus button you can find on the Hayward Aqua Logic or Pro Logic motherboard. If you want to bring the pool chlorinator level up, you will have to press the plus button instead. You will locate the plus and minus buttons in the middle of the control panel. . Classic board game invented by an oscar winning french filmmaker

chlorinator off high salt amps

Sep 15, 2019 · The shock is great but that doesn't address the salt cell and the shock will wear off. Make sure the ph is in the 7.2 to about 7.8 range and your Calcium which is the big reason you have to clean the cell less than 450 ppm. However, when I tested it with the salt strip again, it read 2800ppm. This salt level would be fine for the regular salt chlorinator but I found nothing online about a low salt chlorinator. Does anyone know if 2800ppm is too high for a low salt chlorinator system? I also plan on just taking a sample of water for professional testing tomorrow. If the amps on either reading show zero (0), then you should replace your Main PC Board (GLX-PCB-RITE). If the amps show a reading that isn’t within range, then you should replace your Turbo Cell. High Salt LED ON. The High Salt LED stays on when: The cell amperage is above the maximum limit. You have too much salt in your pool.Split from the Aqua-logic salt too high-cholrinator off high salt/amps topic. Bama I'm having the same exact problem, but did not find any weak or burnt looking soldering points...Also, the back of my board looks a little different then the one pictured. …TCELLS340 generates up to 1.45 lbs. of chlorine per day at high salt or up to 0.725 lbs at low salt levels. TCELLS325 generates up to 0.98 lbs. of chlorine per day at high salt or up to 0.49 lbs at low salt levels. TCELLS315 generates up to 0.53 lbs. of chlorine per day at high salt or up to 0.265 lbs at low salt levels. Aquarite Cell PlatesAstral Pool VX Salt Chlorinator Manual Summary. The user manual for the AstralPool VX salt chlorinator provides detailed information on the installation, operation, maintenance, and troubleshooting of the product. The manual begins with a general overview of the product, followed by instructions for the installation of the control box and the cell.I. ‘High Salt’ Light Stays On. The ‘High Salt’ light will stay on for several reasons including: cell amperage is above the maximum limit, the control is set to the wrong turbo cell, or you simply have too much salt in your pool. The LCD display will read “HI”. Remedies. Independently verify the salt levels in your swimming pool.Jun 1, 2016. #4. Just wanted to post an update on our AquaLogic Hayward t-cell 15 issue. I pulled the board off today and saw a burned solder point. My son and I resoldered the spot, plugged everything in, and now my system is showing amps as well as volts. The reading actually detected salt at the level of 2400 right off the bat.The Aqua Plus is designed to handle the purification needs of most residential swimming pools up to 40,000 gallons (150,000 liters), or the needs of most commercial pools up to 25,000 gallons (95,000 liters). The AQ-PLUS-20 should be used for pools up to 20,000 gallons (75,000 liters).chlorine production by measuring the amps drawn by the chlorinator cell in each polarity. 1. Switch power to the Pool Lab salt chlorinator off at the power outlet and wait at least 10 seconds. 2. If there is a Pool Lab ASP (Auto Sampling Photometer) connected, unplug it from the port at the bottom of the power pack.I have a T-Cell-15, My pool control panel says "Pool Chlorinator 30%" "Chlorinator Off - High Salt Amps" Screen Says "Main Software Revision 2.85" "Display Software Revision 3.11" What do you suggest so that I can get my pool back to salt. Aqua Plus Control Panel.....last year it was saying "no cell power" but doesn't anymore.The “High Salt” light will stay on for several reasons including: cell amperage is above the maximum limit, the control is set to the wrong turbo cell, or, most …SALT changed the modern era in America. Learn more about SALT at HowStuffWorks. Advertisement SALT, in international diplomacy, the common name for negotiations and treaties betwee...Goldline cells will shut down when the current draw gets above 8 amps which can happen with high salt levels and certainly 4400 ppm would shut down the unit. This is done to protect the power supply from high current which can damage components. Also, these units will usually not read high salt unless there is really too much salt.What is you actual salt level, not from the units readout but actual. If the salt is low (1900) the unit will be working harder to try and produce the chlorine which can harm the power unit. Water is more conductive with 3500 salt so less power Volts and amps required. A guy quite recently published a schematic on here and that showed 22.8vGet free real-time information on CHF/SALT quotes including CHF/SALT live chart. Indices Commodities Currencies StocksAdjusting Chlorine Output Pg. 6 High Salt LED ON Pg. 7 No Flow LED flashing or ON Pg. 8 No LED’s/LCD display Pg. 9-12 Low/High Cell temperature Pg. 13 Cell cleaning instructions Pg. 14-16 Troubleshooting flow charts Pg. 17-21 Salt Chart Pg. 22 Software Revision Compatibility Chart Pg. 23 Important Information- Chlorine output and salt Pg. …Apr 8, 2021 · I wanted to share my experience and success in fixing my "Chlorinator Off / High Salt/Amps" issue on my Aquarite panel. I'd replaced my Hayward T-9 with a legit one year before last and it had been working fine. Over the winter I'd been chlorinating the pool manually and maintaining pH--"easy mode" until the heat sets in. .

Popular Topics